To evaluate a diffusionweighted dw black blood mr sequence for the detection of myocardium signal abnormalities in patients with recent myocardial infarction mi. Concurrent correction of geometric distortion and motion. Chen lin, phd dabr 311 outlines epi technique epi pulse sequence characteristics of epi common artifacts associated with epi variants of epi. Clinically, the echo planar flair technique is most helpful in detecting subtle, early lesions that do not enhance, such as early infarct, demyelinating disease, early infection, and trauma. Shottoshot repeatability is the largest difference between integrated errors across waveforms. Multislice perfusionbased functional mri using the fair technique. Point spread function psf map technique for distorti on. Principles and applications of echo planar imaging.
Functional imaging data were acquired with a spin echo echo planar imaging seepi consisting of 250 volumes of 24 axial slices covering the whole brain, with a slice thickness of 4 mm and gap of 1 mm, tr 2 s, te 55 ms. Read download echo planar imaging pdf pdf download. Ghost artifact reduction for echo planar imaging using image phase correction michael h. Mri bolus passage perfusion imaging design perfusion imaging is performed using a timed bolus of contrast given during rapid image acquisition gradient echo echo planar imaging conveys sensitivity to the passage of contrast 2 sec time resolution for each 3d image image intensity becomes hypointense as contrast passes. More recently the term has been expanded to include any rapid gradient echo or spin echo sequence in which k space is traversed in one or a small number of excitations.
Irfanoglu mo, modi p, nayak a, hutchinson eb, sarlls j, pierpaoli c. Advances in gradient and digital data acquisition technology have made it possible to obtain individual mr slices in the time frame of 50100 msec, thus minimizing the effects of patient motion. Integrated imaging of 11cpbr28 pet, mr diffusion and. A standard short tau inversion recovery stir t2weighted sequence was. When the echo planar imaging acquisition strategy is used, the complete image is formed from a single data sample all kspace. Imaging methodology full papers blippedcontrolled aliasing in parallel imaging for simultaneous multislice echo planar imaging with reduced gfactor penalty kawin setsompop,1,2 borjan a. A combination of echo planar imaging and flair imaging offers the image contrast effects of flair imaging and the speed of echo planar imaging. The imaging guidance is devised for initial diagnosis of prostate cancer. Echo planar imaging an overview sciencedirect topics. Study of turbulent flow using halffourier echoplanar imaging. Echo planar imaging another scheme which is sometimes used, especially in brain scanning or where images are needed very rapidly, is called echo planar imaging epi. Echo planar imaging diffusion tensor imaging reversed phase encoding diffeomorphic image registration. As originally defined, echo planar imaging referred to a sequence in which data from all of kspace for an entire 2d plane was collected following a single rfexcitation pulse.
Drbuddi diffeomorphic registration for blipup blipdown diffusion imaging method for correcting echo planar imaging distortions m. Comprehensive reconstruction of multishot multichannel diffusion data using mussels merry mani 1, vincent magnotta, douglas kelley2 and mathews jacob 1university of iowa, ia, usa, 2ge healthcare, usa abstract echo planar imaging epi based magnetic resonance imag. In vivo intravoxel incoherent motion measurements in the. Other sequences acquire one kspace line at each phase encoding step. It is a rapid mri technique that is capable of producing tomographic images at video rates.
Basic mri physics and protocol questions center for. Drbuddi diffeomorphic registration for blipup blipdown. Blippedcontrolled aliasing in parallel imaging for. Echo planar imaging islesssensitive tomotion than is conventional mrimaging andallows imaging ofrapidly changing physiologic processes such asblood flow andkinetic activity. Hutchinsona,b, joelle sarllsc, carlo pierpaolia a section on tissue biophysics and biomimetics, national institute of child health and human development, national institutes of health, bethesda. The scanner is equipped with gradient coils of strength of 44 mt m and a maximum slew rate of 200 tms. This allows ambitious inutero studies such as functional brain imaging with high. A method for continuous accelerated echoplanar imaging. It is not a single specific measurement sequence, but rather a continuum of sequences whereby multiple excitations with multiple gradient. Some imaging departments may add extra sequences to their mpmri prostate protocol if they wish to acquire more information for staging of metastatic prostate cancer and with the subsequent increase in overall scan time. This imaging guidance, planned to diagnose initial. Echo planar imaging is an attractive rapid imaging readout that can image hyperpolarized compounds in vivo.
Dynamic multicoil technique dynamite shimming for echo. To determine whether readoutsegmented echo planar imaging rsepi diffusionweighted imaging dwi can improve the image quality in patients with rectal cancer compared with singleshot echo planar imaging ssepi dwi using 3. Spoiler gradients were applied at the end of the epi sequence in all three directions to destroy any residual transverse magnetization. This is accomplished by rapidly reversing the readout or frequency encoding gradient. In 1977, sir peter mansfield of the university of nottingham described the general principles of echo planar imaging, 1. Susceptibilityinduced distortion correction in hyperpolarized echo planar imaging jack j. Efficient correction of inhomogeneous static magnetic fieldinduced distortion in echo planar imaging. In echo planar imaging epi, constant and dynamic offresonances produce image shifts most notably along the phaseencoding direction. This is a pdf file of an unedited manuscript that has been accepted for publication. Generically, this acquisition mode is known as echoplanar imaging epi. Here, we propose a method to correct for the respective artifacts by computing the offresonance frequency from phase differences between two kspace echos of the phase correction scan in epi sequences. Echoplanar imaging epi questions and answers in mri. The technique is a hybrid, whereby the advantages of gradient.
Standard pulse sequences areused toobtain echo planar images, which have diagnostic utility similar tothatofconventional mrimages. Epi echo planar imaging is one of the early magnetic resonance imaging sequences also known as intascan, used in applications like diffusion, perfusion, and functional magnetic resonance imaging. As a service to our customers we are providing this early version of the manuscript. Drbuddi diffeomorphic registration for blipup blipdown diffusion imaging method for correcting echo planar imaging distortions, neuroimage. Narayana1 the in vivo apparent diffusion tensor adt of spinal cord was measured in nine rats at 2. C liao, mk manhard, b bilgic, q fan, h wang, s han, dj park, f wang. Absolute correction of b 0 fluctuations in echoplanar imaging. By alternating the sign of the phase encoding gradient waveform.
A, 3barron neurological institure, phonenix, az, united states, 4wake. In vivo diffusion tensor imaging of rat spinal cord with. A medical imaging technique that records changing magnetic fields also called nuclear magnetic resonance nmr. Echo planar imaging epi is the fastest imaging sequence currently available and has the potential to revolutionize many aspects of mr technology. Echo planar imaging epi is an mri technique of particular value to neuroscience, with its use for virtually all functional mri fmri and diffusion imaging of fiber connections in the human brain. Tsekos1 and james ashe2 1center for magnetic resonance and department of radiology, university of minnesota medical. Full optimization by tuning to the gradient frequency response functions allows for a maximally timeefficient scan within safe limits. The scanner is equipped with multi band echo planar imaging, spectroscopic imaging, and multinuclear imaging capabilities. This switching or reversal may also be done in a sinusoidal. Simultaneous multislice echo planar imaging with blipped.
Multislice perfusionbased functional mri using the fair. Diffusionweighted echo planar imaging in patients with. Echo planar imaging epi pulse sequences can provide diffusion encoding diffusion along the direction of an applied magnetic gradient signal decrease by applying linear gradients in different axes, diffusivity may be measured in different directions a volume is. Echoplanar flair imaging in evaluation of intracranial. Echo planar imaging epi fast spin echo fse slow 3mins faster 10 seconds t2weighted image. Concurrent correction of geometric distortion and motion using the mapslicetovolume method in echo planar imaging desmond t. Additionally, the department of radiology has research agreements in place with ge healthcare to. Spin echo 180 pulse after tip pulse prince pulse sequence. Dynamic multicoil technique dynamite shimming for echo planar imaging of the human brain at 7 tesla. Echo planar imaging pulse sequences echo planar image reconstruction echo planar imaging image artifacts physiological side effects of fast gradient switching echo planar imaging angiography diffusion imaging with echo planar imaging echo planar imaging of the abdomen abdominal diffusion imaging using echo planar imaging.
Epi generates a single 2d image in a fraction of a second. Wald1,2,4 simultaneous multislice echo planar imaging epi. When the echo planar imaging acquisition strategy is used, the complete image is formed from a single data sample all kspace lines are measured in one repetition time of a gradient echo or spin echo sequence see single shot technique with an acquisition time of about 20 to 100 ms. Comparison of cbf and bold effects seonggi kim,1w nikolaos v. Buonocore, lisheng gao an algorithm is described for reducing ghost artifacts in echo planar imaging epi using phase corrections derived from images reconstructed using only even or odd kspace lines. Magnetic resonance imaging mri exploration of the human. Diffusion imaging applications in neuropsychiatric disorders. One slice per patient was acquired with b 0 and b 50 smm2. Echo planar imaging is performed using a pulse sequence in which multiple echoes of different phase steps are acquired using rephasing gradients instead of repeated 180 degree radio frequency pulses following the 90180 in a spin echo sequence this is accomplished by rapidly reversing the readout or frequency encoding gradient. Ghost artifact reduction for echo planar imaging using. Joint virtual coil reconstruction with background phase matching for highly accelerated diffusion echo planar imaging. However, mr imaging hardware and computer limitations prevented the technique from being used outside of a laboratory setting.
In vivo diffusion tensor imaging of rat spinal cord with echo planar imaging david a. Echo planar imaging cspiral dradial each method has its own. Pdf echoplanar imagingmagnetic resonance imaging in a. The mbest 9 echo planar encoding sequence was used, with the switched gradient sinusoidally modulated at 0.
257 1042 1554 708 441 1242 1130 45 449 981 898 999 301 1043 390 1521 301 685 992 914 1392 20 238 899 602 370 787 1511 174 782 1290 445 336 782 79 652 1295 1355 153 653 414 25 677 502 858 358